Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstract
Abstracts
Author Reply
Author's Reply
Book Review
Brief Communication
Case Report
Case Series
Commentary
Continuing Medical Education
Diagnosis
Down the Memory Lane
Editorial
Erratum
Faculty
Free papers: Oral Session
Free papers: Poster Session
From Editor's desk
From The Chair, Scientific Committee
Guest Editorial
Image Challenge
In Memoriam
Interesting Image
Interesting Images
Invited Review
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Message
Message by President Elect, SNM, India
Message by President, SNM, India
Messages
Obituary
Oral
ORAL PRESENTATION
Original Article
Pictorial Essay
Pictorial Teaching Essay
POSTER PRESENTATION
President's Message
Presidents’ Wall of Fame
Review
Review Article
Schedule for Paper Presentations
Scientific Program
Secretary's Message
Short Communication
SNM India Guidelines 1.0
Technical Communication
Technical Note
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Abstract
Abstracts
Author Reply
Author's Reply
Book Review
Brief Communication
Case Report
Case Series
Commentary
Continuing Medical Education
Diagnosis
Down the Memory Lane
Editorial
Erratum
Faculty
Free papers: Oral Session
Free papers: Poster Session
From Editor's desk
From The Chair, Scientific Committee
Guest Editorial
Image Challenge
In Memoriam
Interesting Image
Interesting Images
Invited Review
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Message
Message by President Elect, SNM, India
Message by President, SNM, India
Messages
Obituary
Oral
ORAL PRESENTATION
Original Article
Pictorial Essay
Pictorial Teaching Essay
POSTER PRESENTATION
President's Message
Presidents’ Wall of Fame
Review
Review Article
Schedule for Paper Presentations
Scientific Program
Secretary's Message
Short Communication
SNM India Guidelines 1.0
Technical Communication
Technical Note
View/Download PDF

Translate this page into:

Interesting Images
32 (
4
); 359-360
doi:
10.4103/ijnm.IJNM_68_17

Abnormal Fluorodeoxyglucose Uptake in Lung without Structural Abnormality on Computed Tomography

Department of Nuclear Medicine and PET-CT, Basavatarakam Indo American Cancer Hospital, Hyderabad, Telangana, India
Department of Radiology, Basavatarakam Indo American Cancer Hospital, Hyderabad, Telangana, India

Address for correspondence: Dr. Prathyusha Bikkina, Department of Nuclear Medicine and PET-CT, Basavatarakam Indo American Cancer Hospital, Road No. 14, Banjara Hills, Hyderabad - 500 034, Telangana, India. E-mail: prathyushabikkina@gmail.com

Licence

This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

Disclaimer:
This article was originally published by Medknow Publications & Media Pvt Ltd and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) is a useful proven imaging modality in the management of many types of cancers. It is being used at various stages of treatment of cancer. Knowledge regarding the physiological biodistribution and false-positive findings should be kept in mind for correct interpretation. Pulmonary FDG uptake can be due to different causes such as infection, inflammation, and metastases which are invariably associated with structural abnormality on CT. In rare circumstances, there can be a focus of FDG uptake in the lung with no corresponding structural abnormality which might be due to an inflammatory vascular microthrombus or due to iatrogenic microembolism caused during the injection of radiotracer. It is important to be aware of this as it can cause difficulty in interpreting the scan and can lead to false-positive findings. It also highlights the importance of hybrid imaging in the form of PET-CT as there is a definite possibility of misinterpreting this as a site of metastasis in a known carcinoma patient if there was no corresponding CT image.

Keywords

False positive
fluorodeoxyglucose positron emission tomography-computed tomography
iatrogenic
microthrombus and embolism

A 55-year-old patient who is a treated case of tongue carcinoma presented with clinical recurrence. He was referred for a restaging fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) scan. FDG PET-CT images demonstrated a focal area of abnormal tracer uptake in the left lung lower lobe with no corresponding structural abnormality on CT images [Figure 1] in addition to local recurrence and lymph nodal metastases. A repeat FDG PET-CT scan done after a short interval of 5 days showed complete resolution of the FDG focus in the left lung [Figure 2].

(a) Maximum intensity projection image showing focal fluorodeoxyglucose uptake in the left lung. (b) Focal fluorodeoxyglucose uptake in the left lung lower lobe without structural abnormality
Figure 1 (a) Maximum intensity projection image showing focal fluorodeoxyglucose uptake in the left lung. (b) Focal fluorodeoxyglucose uptake in the left lung lower lobe without structural abnormality
(a) Maximum intensity projection image of limited positron emission tomography-computed tomography chest with no focal abnormal fluorodeoxyglucose uptake. (b) Follow-up scan after 5 days showing resolution of fluorodeoxyglucose focus
Figure 2 (a) Maximum intensity projection image of limited positron emission tomography-computed tomography chest with no focal abnormal fluorodeoxyglucose uptake. (b) Follow-up scan after 5 days showing resolution of fluorodeoxyglucose focus

Pulmonary FDG uptake can be due to different causes such as infection, inflammation, and metastases. These causes are always associated with definite structural abnormality on the corresponding CT sections. In rare circumstances, there can be a focus of FDG uptake in the lung with no corresponding structural abnormality. There are two main reasons to this finding – it can either be due to an inflammatory vascular microthrombus or due to iatrogenic microembolism caused during the injection of radiotracer. Thrombus formation during the injection of FDG can lead to formation of these microemboli. The mechanism thought to be related to this is the formation of an active thrombus at the site of vascular injury. The activated platelets in the thrombus have higher energy requirements in the form of glucose and consequently take up FDG and show as a focus of FDG uptake without corresponding structural abnormality. We assume that in our case, this is due to iatrogenic pulmonary microembolism.

There are few instances of this finding in the literature.[123456789] All the reported cases showed resolution of FDG uptake in the repeat scans done few weeks to few months later. There was a single report which showed resolution of FDG focus in a brief interval of 4 days. In our case too, there is resolution of FDG focus in a brief interval of 5 days. A repeat scan is necessary to check for resolution of FDG focus and to exclude other consequences such as consolidation and atelectasis.

It is important to be aware of this as it can cause difficulty in interpreting the scan and can lead to false-positive findings. It also highlights the importance of hybrid imaging in the form of PET-CT as there is a definite possibility of misinterpreting this as a site of metastasis in a known carcinoma patient if there was no corresponding CT image.

In conclusion, knowledge of the causes for abnormal FDG uptake without corresponding structural abnormality should be known as this can lead to false-positive results. Follow-up scan should be done to exclude any dire consequences. FDG administration should be done with an indwelling intravenous (IV) cannula rather than direct IV injection to prevent vascular injury and subsequent thrombus formation.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

References

  1. , , , . Pulmonary radioactive microemboli following radionuclide venography. J Nucl Med. 1977;18:1140-1.
    [Google Scholar]
  2. , , , , , , . Pulmonary FDG uptake without a CT counterpart - A pitfall in interpreting PET/CT images. Acta Radiol. 2011;52:513-5.
    [Google Scholar]
  3. , , , . Iatrogenic FDG foci in the lungs: A pitfall of PET image interpretation. Eur Radiol. 2003;13:2122-7.
    [Google Scholar]
  4. , , , , , . Focal F-18 fluoro-deoxy-glucose accumulation in the lung parenchyma in the absence of CT abnormality in PET/CT. J Comput Assist Tomogr. 2007;31:800-5.
    [Google Scholar]
  5. , , , , , , . Incidental focal F-18 FDG accumulation in lung parenchyma without abnormal CT findings. Ann Nucl Med. 2009;23:599-603.
    [Google Scholar]
  6. , , . Increased (18)F-fluorodeoxyglucose uptake in benign, nonphysiologic lesions found on whole-body positron emission tomography/computed tomography (PET/CT): Accumulated data from four years of experience with PET/CT. Semin Nucl Med. 2007;37:206-22.
    [Google Scholar]
  7. , , . PET and PET/CT: A Clinical Guide (2nd ed). Stuttgart, Germany: Thieme Publishers; . p. :53-4.
  8. , , . An intense F-FDG pulmonary microfocus on PET without detectable abnormality on CT: A manifestation of an iatrogenic FDG pulmonary embolus. Biomed Imaging Interv J. 2010;6:e37.
    [Google Scholar]
  9. , . Focal FDG Uptake in Lung Parenchyma Without Structural Alterations on CT. World J Nucl Med. 2013;12:38-40.
    [Google Scholar]
Show Sections